|
|
Hay dos tipos de inversores: |
|
Tenemos la distribución de la marca Wave. With an authorize distribution of the WAVE inverters. This inverter synchronizes and can be Stacked with all Xantrex/Trace |
| 1.5 Kw - Modelo WAVE1524: 1,500 Watts @ 24 V DC input - 120 V AC output | 2 X WAVE1524 Unidos en paralelo (stackable) 3,000 watts @ 24V DC - 240 V AC 2.5 Kw - Modelo WAVE2524: 2,500 Watts @ 24 V DC input - 120 V AC output 2 X WAVE2524 Unidos en paralelo (stackable) 5,000 watts @ 24V DC - 240 V AC 3.6 Kw - Modelo WAVE3624: 3,600 Watts @ 24 V DC input - 120 V AC output 2 X WAVE3624 Unidos en paralelo (stackable) 7,200 watts @ 24V DC - 240 V AC 5.5 Kw - Modelo WAVE5536: 5,500 Watts @ 36 V DC input - 120 / 220 V AC output 2 X WAVE5536 Unidos en paralelo (stackable) 11,000 watts @ 36 V DC - 240 V AC 8.0 KW - Modelo WAVE8036: 8,000 Watts @ 36 V DC input - 120 / 220 V AC output 2 X WAVE8036 Unidos en paralelo (stackable) 16,000 watts @ 36 V DC - 240 V AC |
|

| OutBack FX (sellado) 2.0 Kw - Modelo FX2012T: 2,000 Watts @ 12 V DC input - 120 V AC 60Hz output 10 X FX2012T Max. en serie. 20,000 watts @ 12 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. 2.5 Kw - Modelo FX2524T: 2,500 Watts @ 24 V DC input - 120 V AC 60Hz output 10 X FX2524T Max. en serie. 25,000 watts @ 24 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. 3.0 Kw - Modelo FX3048T: 3,000 Watts @ 48 V DC input - 120 V AC 60Hz output 10 X FX3048T Max. en serie. 30,000 watts @ 48 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. |
OutBack VFX (ventilado) 2.8 Kw - Modelo VFX2812: 2,800 Watts @ 12 V DC input - 120 V AC 60Hz output 10 X VFX2812 Max. en serie. 28,000 watts @ 12 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. 3.5 Kw - Modelo VFX3524: 3,500 Watts @ 24 V DC input - 120 V AC 60Hz output 10 X VFX3524 Max. en serie. 35,000 watts @ 24 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. 3.6 Kw - Modelo VFX3648: 3,600 Watts @ 48 V DC input - 120 V AC 60Hz output 10 XVFX3648 Max. en serie. 36,000 watts @ 48 V DC - 120 V AC 60 Hz Sinusoidal/Sine wave. |
La serie Outback FX de diseño modular es el inversor /cargador de onda sinusoidal pura ampliable hasta 30Kw, que puede ser utilizado tanto para pequeños como para grandes sistemas de energía (desde 2kw hasta 30 Kw). Adicionalmente el FX puede ser conectado en paralelo para dar 240 volts, hasta se puede conectar tres Outback FX en conexión trifásica. Pueden conectarse hasta 10 equipos en paralelo para obtener 30Kw. Tan sólo con conectar los inversores al Hub y ellos mismos se auto sincronizarán. Arranque de grupo automático. Si hubiesen varios inversores conectados estos funcionarán en base a las cargas, estando los inversores excedentes en suspensión, ahorrando de este modo energía.
El Outback Fx está diseñado para sobrevivir en las condiciones más duras en cualquier parte del mundo. Sus juntas herméticas y el chasis de aluminio protegen y mantienen la temperatura de los componentes de conversión. Sin requerir aire del exterior para enfriar los componentes electrónicos. Esto reduce en un 80% fallos de los inversores: corrosión, polvo, insectos y daños de animales
El FX puede ser utilizado en aplicaciones con temperaturas superiores a 60ºC con un reducido rating de salida.


| ONDA SEMI-CUADRADA MODIFIED SINE WAVE 1.5 Kw - Modelo DR1524: 1,500 Watts @ 24 V DC input - 120 VAC output 3,000 watts @ 24V DC - 240 V AC | 2 X DR1524 Unidos (stackable) 2.5 Kw - Modelo DR2524: 2,500 Watts @ 24 V DC input - 120 VAC output 5,000 watts @ 24V DC - 240 V AC| 2 X DR2524 Unidos (stackable) 3.6 Kw - Modelo DR3624: 3,600 Watts @ 24 V DC input - 120 VAC output 7,200 watts @ 24V DC - 240 V AC| 2 X DR3624 Unidos (stackable) |
ONDA SINUSOIDAL/ SINE WAVE 5.5 Kw - Modelo SW5548: 5,500 Watts @ 48 V DC input - 120 V AC output 11,000 watts @ 48 V DC - 240 V AC Sinusoidal/ Sine wave. | 2 X SW5548 Unidos (stackable) 4.0 Kw - Modelo SW4024/SW4048: 4,000 Watts @ 24/48 V DC input - 120 V AC output 8,000 watts @ 24 V DC - 240 V AC Sinusoidal/Sine wave. | 2 X SW4024 Unidos (stackable) |
XANTREX/ TRACE ENGINEERING
Tenemos inversores Trace Engineering / Xantrex el cual es considerado uno de los mejores
Xantrex antes Trace Engineering, ofrece inversores para casi todas las aplicaciones, pequeñas o grandes necesidades de potencia, Xantrex inversores están certificadas a las normas de to North American standards, las pruebas llevadas a cabo por ETL (Laboratorios de Pruebas Ambientales), una compañía totalmente independiente de pruebas, o por UL (Underwriters Laboratories).
Xantrex formerly Trace Engineering, offers inverters for almost every conceivable application from small power needs to large, 500 watts up to 11,000 watts of continuous power. Xantrex inverters and accessories are fully certified to North American standards, testing conducted by ETL (Environmental Testing Laboratories), a fully independent testing company, or by UL (Underwriters Laboratories).
DR Series de Xantrex / Trace Engineering:
Desde 1,500 watts hasta 3,600 Watts, 7,200 Watts Unidos en Paralelo (stackable) de carga continúa. Este modelo tiene una gran eficiencia y capacidad para los arranques de corriente inductiva (motores).
Este modelo se puede Unir (Stackable) en paralelo, para dar 240 volts AC mediante un cable RJ11.

SMA América Sunny Island 5048U
Podras con este equipo desconectarse de la red electrica y sincronizar todo tipo de fuente de energia renovable
la nueva generación de SMA, los inversores Sunny Island combinan la más avanzada tecnología utilizada en sus Sunny Boys con un excelente conjunto de características la independencia eléctrica con paneles solares. El nuevo Sunny Island 5048U se caracteriza por su increíble fuerza de arranque y excelente potencia. Cada unidad proporciona 120 VAC de salida estable y limpia, completamente senoidal.
Se puede configurar mas de una unidades en una sola fase, mono-fasica o trifásica.
También cuenta con un exclusivo sistema de acoplamiento AC de fuentes de energía, donde usted puede eficientizar y sacar el mayor provecho a todas las fuentes de energías disponibles reuniéndolas en un solo punto de diversión.
El Sunny Island 5048U también ayuda a optimizar la vida útil de las baterías a través de su avanzado sistema de manejo de batería.
Este inversor también puede utilizarse como un sistema de BACK UP en caso de apagones.







